Sensor Averaging¶
The card can automatically calculate and display averaged sensor readings by device class, using the same logic as Home Assistant's area card.
By default these sensor classes will be averaged.
- temperature
- humidity'
- illuminance
How Averaging Works¶
- Discovery: Finds all sensors in the area with specified device classes
- Filtering: Only includes numeric sensors with valid states
- Grouping: Groups sensors by unit of measurement within each device class
- Calculation: Calculates simple average for each group
- Display: Shows averaged value with appropriate formatting
Area Default Sensors¶
When an area has default temperature or humidity sensors configured (via Home Assistant's area settings), the card will:
- Use the area's default sensors instead of automatically collecting all sensors of that device class
- Prevent duplicates by skipping other temperature/humidity sensors when defaults are set
- Display the default sensor as part of the averaged sensors (or as a single sensor if it's the only one)
This ensures that when you've configured specific sensors as defaults for an area in Home Assistant, the card respects that choice and uses those sensors rather than averaging all sensors of that type.
Example:
# Area "shed" has configured:
# temperature_entity_id: sensor.shed_climate_air_temperature
# humidity_entity_id: sensor.shed_climate_humidity
sensor_classes:
- temperature
- humidity
# Card will use sensor.shed_climate_air_temperature and sensor.shed_climate_humidity
# Other temperature/humidity sensors in the area will be ignored

Averaging Examples¶
Temperature Sensors¶
# Area has these temperature sensors:
# sensor.room_temp_1: 72.5°F
# sensor.room_temp_2: 71.8°F
# sensor.room_temp_3: 73.1°F
sensor_classes:
- temperature
# Displays: "72.5°F" (average of the three sensors)
Mixed Units¶
# Area has temperature sensors with different units:
# sensor.temp_celsius: 22.5°C
# sensor.temp_fahrenheit_1: 72°F
# sensor.temp_fahrenheit_2: 74°F
sensor_classes:
- temperature
# Displays:
# "22.5°C" (single Celsius sensor)
# "73°F" (average of Fahrenheit sensors)
Advanced Configuration¶
# Complete sensor configuration
sensors:
- sensor.special_co2_sensor # Individual sensor (shown first)
- sensor.important_pressure # Individual sensor (shown first)
sensor_classes:
- temperature # Averaged (shown after individual)
- humidity # Averaged (shown after individual)
- illuminance # Averaged (shown after individual)
- battery
- voltage
sensor_layout: bottom # Display location
Numeric Device Classes¶
The following device classes are supported for averaging (must be numeric sensors):
temperature,humidity,pressure,illuminance,co2,pm25,pm10,aqi,battery,energy,power,voltage,current, and more.
Reference: See Home Assistant's area card documentation for the complete list.
Climate Thresholds Integration¶
Individual sensors can also be used for climate thresholds, even when their device class isn't included in sensor_classes. This is useful when you want to:
- Use specific sensors for climate calculations while excluding others
- Configure thresholds without including all sensors of that device class in averaging
Example: Selective Climate Thresholds¶
sensors:
- sensor.living_room_temp_1 # Individual temperature sensor
- sensor.basement_temp # Different temperature sensor
sensor_classes:
- pressure # Only pressure sensors from area
thresholds:
temperature:
- entity_id: sensor.living_room_temp_1
value: 75 # Uses living room temp only
In this configuration:
sensor.living_room_temp_1is used for climate thresholds (if it hasdevice_class: temperature)sensor.basement_tempis shown individually but not used for thresholds- No temperature averaging occurs since
temperatureisn't insensor_classes - Pressure sensors from the area are averaged as usual
Threshold Lookup Priority¶
When entity_id is specified in a threshold entry, the system looks for the sensor in this order:
- Individual sensors (from
config.sensors) - if the entity has the correct device class - Averaged sensors (from
config.sensor_classes) - as a fallback
This ensures that configured individual sensors take priority over area-wide averages for climate calculations.